Free Breathing Motion Corrected Pixel-wise MRI Myocardial T1 Parameter Mapping for Clinical Cardiac Imaging

This technology includes a method for performing cardiac imaging without the need for the patient to hold their breath. Free breathing pixel-wise myocardial T1 parameter mapping includes performing a free-breathing scan of a cardiac region at a plurality of varying saturation recovery times to acquire a k-space dataset; generating an image dataset based on the k-space dataset; and performing a respiratory motion correction process on the image dataset.

Methods and Systems for Automatically Determining Magnetic Field Inversion Time of a Tissue Species

This technology includes a computer-implemented method for determining magnetic field inversion time of a tissue species using a T1-mapping image, information about the region of interest, and a tissue classification algorithm. This method includes T1-mapping image comprising a plurality of T1 values within an expected range of T1 values for the tissue of interest. An image mask is created based on predetermined identification information about the tissue of interest. Next, an updated image mask is created based on a largest connected region in the image mask.

Prior Enhanced Compressed Sensing (PRINCE-CS) Reconstruction for Dynamic 2D-radial Cardiac MRI

This technology includes a method to reduce scanning time while retaining high image quality during MRI scans. A reconstructed image is rendered from a set of MRI data by first estimating an image with an area which does not contain artifacts or has an artifact with a relatively small magnitude. Corresponding data elements in the estimated image and a trial image are processed, for instance by multiplication, to generate an intermediate data set.

A Pre-emphasis Technique Based on the Temperature-dependent Gradient System Behavior for Trajectory Correction in MR Imaging

This technology includes the determination of temperature dependent temporal deviations of the real from the intended gradient waveforms and k-space trajectories during MRI image acquisition, and the use of appropriate temperature dependent pre-compensations to avoid or reduce the image distortion caused by these temporal deviations on the gradient waveforms and k-space trajectories, which will improve imaging quality.

Phase Sensitive Motion Correction and T1 Mapping for Cardiovascular Magnetic Resonance Imaging

This technology includes a method of correcting the motion during T1 mapping using cardiovascular magnetic resonance imaging (MRI). Ischemic heart disease is the leading cause of death in the United States. The lack of blood supply among myocardial tissue, especially for scar regions, changes the T1 relaxation value of heart muscles. The non-invasive quantification of T1 value of myocardium (T1 mapping) is therefore of great importance for the diagnosis and treatment of cardiovascular disease.

Background-free Imaging by Selective Modulation of Nanodiamond Fluorescence Using a Magnetic Field

This technology includes the use of nanodiamonds to achieve background-free imaging. We present several techniques to reduce or eliminate background florescence by exploiting properties of the fluorescent nanodiamonds. In particular, magnetic field modulation of the fluorescence intensity offers a simple, robust, and easily adaptable method to obtain background free imaging in a variety of imaging modalities, i.e., fluorescence microscopy and wide field fluorescence animal imaging.

Mass Spectrometry Derived Protein Biomarkers of Atherosclerotic Cardiovascular Disease Risk

This technology includes a combination of protein biomarkers and clinical risk factors to be used as an In Vitro Diagnostic Multivariate Index Assay (IVDMIA) that can improve the identification of individuals at high risk for atherosclerotic cardiovascular disease (ASCVD) and myocardial infarction (MI). Incorporation of novel protein biomarkers of ASCVD risk into risk assessment algorithms may improve their ability to identify individuals at high risk for ASCVD.

Software for Fully Automating Myocardial Perfusion Quantification

Software is has been developed and available for licensing that fully automates image processing for the quantification of myocardial blood flow (MBF) pixel maps from firstpass contrast-enhanced cardiac magnetic resonance (CMR) perfusion images. The system removes the need for laborious manual quantitative CMR perfusion pixel map processing and can process prospective and retrospective studies acquired from various imaging protocols. In full automation, arterial input function (AIF) images are processed for motion correction and myocardial perfusion images are corrected for intensity bias.

Real-time Cellular Thermal Shift Assay and Analysis (RT-CETSA) for Research and Drug Discovery

Scientists at NCATS have developed a novel Cellular Thermal Shift Assay (CETSA), named “Real-time CETSA” in which temperature-induced aggregation of proteins can be monitored in cells in real time across a range of compound concentrations and simultaneously across a temperature gradient in a high-throughput manner. Real-time CETSA streamlines the thermal shift assay and allows investigators to capture full aggregation profiles for every sample.